WaveZero's Form/Met® EMI suppression products are the optimum choice for new product development and design teams. These EMI/RFI shielding materials are created by thermoforming and die cutting a lightweight plastic substrate and then metalizing the substrate with a pure metal or combinations of layers to make the shield conductive. Product designers can use Form/Met shields to achieve regulatory compliance at: 1) Enclosure level, 2) Board / system level, or 3) Component level, making it the most flexible electromagnetic shielding solution available for EMI/RFI mitigation. The innovative Form/Met approach replaces more costly and less effective solutions deploying conduction gaskets, conductive paint, soldered metal cans, or conductive plastics.

WaveZero offers customers an array of new benefits and features to make their products comply with EMC and environmental recycling regulatory requirements.

Technical Data (214 KB)

Features

  • High performance shielding from advanced metal coating systems
  • Surface resistivity measurements between 0.02 and 0.5 Ohms/Square inch (standard aluminum)
  • Exceptional design flexibility
  • 30 dB to 60dB of shielding effectiveness is typical
  • Lightweight (20% the weight of metal)
  • Low cost tooling
  • Recyclable and environmentally sound
  • Economical - low total cost of ownership

Benefits

  • Rapid time-to-market (via design-in of economic shield solution)
  • Economical prototyping
  • Highly scalable (low NRE and tooling costs)
  • Facilitates environmental regulatory compliance
  • Enables electromagnetic compatibility and electromagnetic compliance (EMC)

Product Types

WaveZero offers three main approaches in the design of EMI shielding and electronic products:
  • Enclosure Shield
  • Board / System Shield
  • Component Shield

Enclosure Level Shield

Designed to conform to the inner contours of your product's enclosure, the enclosure level shield completely encapsulates the printed circuit board (PCB). Ventilation and access holes for connectors and wiring can be easily incorporated into the shield's design. Integrating two or more designed-in shield features achieves grounding with corresponding grounding points in the PCB. The ability to provide a pseudo-Faraday cage results in a superior EMI/RFI shielding system compared to other alternatives.


Figure 1: Enclosure shield with common feature

Board / System Level Shield

WaveZero's patented technology, along with years of Form/Met design experience, enables shielding solutions that are cost-effective at any volume and deliver high performance. EMI shield designs are not restricted to straight edges or square forms, and complex shapes can be integrated into any electronic product design.

Attachment and grounding of the electromagnetic shield to the circuit board is accomplished through dispensed electrically conductive adhesives (DECA), die-cut, conductive pressure sensitive adhesives (PSA), or mechanical fasteners.


Figure 2: Board / System shield with common features

Component Level Shield

WaveZero's compartmentalized electromagnetic shielding solutions replace one or more sheet metal cans with a single shield component comprised of multiple compartments. WaveZero designs EMI shields at the component level for any specific challenge.


Figure 3: Component shield with common features

Product Options

Product Types:

  • Enclosure
  • Board / System
  • Component

Metallized Surface(s)

  • Inside
    • Metallized surface faces inward towards the circuit board
    • Used with DECA, PSA, mechanical fasteners
  • Outside
    • Metallized surface faces outward from the circuit board
    • Used with mechanical fasteners
  • Both sides
    • All surfaces metallized, including edges
    • Improves shielding performance of basic material by 5dB (300 MHz) - 30 dB (3 GHz) in most cases

Metallizing Materials

  • Single Material System
    • Aluminum (99.8% pure)
      • Standard EMI coating suitable for most applications
      • Least expensive coating material
      • Excellent EMI shielding performance over a wide range of frequencies
      • Nontoxic to humans and environment
    • Copper
    • Tin
    • Silver
    • Nickel
    • Stainless Steel
  • Multi-Material (Multi-Layer Systems)
    • Improved performance at lower frequencies (between 1 MHz and 50 MHz)
    • Stainless Steel/Aluminum
    • Stainless Steel/Copper/Stainless Steel/Nickel
    • Stainless Steel/Copper/Copper/Stainless Steel

Attachment Method

  • Dispensed Adhesive (Board/System/Component)
    • Silver filled thermoplastic is applied to the flange areas of the and is used to mount the shield to the PCB
    • Requires 1 mm minimum ground trace on PCB Mechanical
  • Snap Features (Enclosure/Board/System)
    • Can mate with corresponding holes in PCB to mount the shield
    • Can mate with corresponding holes in shield to enclose the PCB between the shield
  • Mechanical (All Types)
    • Screws or similar fasteners pass through holes in the flange of the shield and mount the shield to the PCB.
  • Pressure Sensitive Adhesive (PSA) (Board/System)
    • Conductive PSA is applied to the flange areas of the shield and is used to mount the shield to the PCB
    • Generally requires 2 mm minimum ground trace on mating PCB

    Substrate Materials

    • Material gauge availability for all material types is typically between .010" - .030".
    • All material types have a UL V0 flame rating.
    • Available substrates:
      • Polyvinyl Chloride (PVC)
        • Performs up to 72°C
      • Polybutylene Terepthalate (PBT)
        • Material performs up to 135°C
      • Polycarbonate (PC)
        • Material performs up to 130°C

    Formed Features

    • Number of Cavities:
      • Can be integrated on all EMI/RFI shield types
    • Ribs
      • Used to strengthen large, flat surfaces
    • Bosses and Standoffs
      • Used to support the shield off of the PCB or attachment surface

    Number of Cutting Planes

    • Perimeter Flange Cut
      • Generally required to remove shield from excess material
    • Flange Cuts
      • For additional holes and cutouts on the flange in addition to the perimeter cut these features have additional locational tolerance requirements from the perimeter flange cut.
    • Secondary Parallel Cutting Planes
      • 1 - 2 cutting planes standard
      • Additional cutting planes increase tooling and piece part pricing.

    Shield Size

    Length x Width x Depth

    Custom Model Options

    • Sidewall Cutting Features
      • Cuts on vertical sidewalls increase tooling and piece part pricing.
    • Living Hinge
      • Typically for enclosure level shields
    • Tape and Reel
      • Width of Reel:
      • Available for high-volume Component Shields of appropriate size and geometry.
    • Dispensed, conductive adhesive for attaching and grounding the shield
      • Generally requires a 1 mm ground trace minimum
      • Material:
        • Silver filled thermoplastic
          • Cure temperatures of approximately 140°C
          • Stable adhesive which can be shipped pre-dispensed on the shield
          • Excellent conductivity
        • Silver filled epoxy
          • Varying cure temperatures between room temperature and 80°C
          • Excellent conductivity
        • Carbon filled resins
          • Varying cure temperatures and conductivity
          • Good conductivity

    Product Model Options Summary Table
      Component Board / System Enclosure
    Material Substrate
    PVC X X X
    PC X X X
    PBT X X X
    Thermoform Features
    Cavities X X X
    Living Hinge X
    Snap Features X X
    Cutting Tooling
    Steel Rule Dies X X X
    Matched Metal Dies X
    Cut Features
    Primary cutting Plane X X X
    Secondary Plane X X
    Sidewall cuts X
    Metalization Scheme
    Single Sided X X X
    Double Sided X X X
    Metalization Type
    Aluminum X X X
    Ss/Cu/Cu/Ss X X X

    PCB Design for Manufacturing with Form/Met

    Introduction
    Form/Met® EMI shielding products enable OEMs to achieve electromagnetic compliance for their electronic designs while assuring economical volume manufacturing. OEMs are encouraged to understand the benefits of deploying the Form/Met® technology during initial conceptual development. Proper PCB design, as delineated below, provides electromagnetic shield designers and their clients with the assurance that prototype designs can pass EMC tests quickly with no need for board rework or less effective and more costly "fixes."

    Board Shield
    A few simple rules applied during the early stages of shielding design and prior to initial board layout assures the easy use of Form/Met®.

    Ground traces - Components and circuits known or suspected of creating potential compliance problems should be isolated from adjacent features on the board with the use of guard traces. Ground traces should be 1 mm in width or greater when dispensed adhesives are used for attachment (2 mm for pressure sensitive adhesives). If size constraints dictate smaller width traces, consult WaveZero for solutions involving sub-millimeter guard trace widths.

    Component placement - Form/Met® EMI shields are often formed with a very small draft angle to facilitate removal from the thermoforming mold. To avoid interference of the electromagnetic shield sidewall with a component, the component should be placed a minimum of H/4 mm away from the closest edge of the trace where H is the height of the component. Consult WaveZero when tighter component placement is required.

    Enclosure Shield
    Form/Met® enclosure shields surround the printed circuit board and fit within the inside surface of the plastic housing.

    Housing dimensions - The spacing between the edge of the printed circuit board and the inner surface of the housing (X) should allow for the thickness of the Form/Met® shield. For a nominal EMI/RFI shield thickness of T, the spacing should be a bit larger to allow for manufacturing tolerances and to facilitate assembly. In a typical situation, where T is 0.010 inches (standard Form/Met® film thickness), and the designer believes that 0.003 inches is the preferred assembly tolerance, then X would be 0.013 inches.

    "Z" stack tolerances - When designers develop electronic products with constraints on the overall product thickness, it may be possible to use designed-in features in the plastic housing and/or the Form/Met® shield to hold the Form/Met® EMI shield solidly against the ground traces of the PCB. This application eliminates adhesives and mechanical forms of attachment. Consult WaveZero for implementing this design attribute.

    Shield Assembly Processes
    WaveZero delivers complete EMI shields to the OEM's manufacturer. If the manufacturer is not already a certified Form/Met® assembler, the manufacturer can be rapidly trained and certified. Virtually all manufacturers possess the necessary equipment for the assembly of Form/Met® EMI/RFI shields.